| Aplikasyon: | Laboratwa endistriyèl, Lopital, Klinik Veterinè, Laboratwa Manje, Inivèsite ak Kolèj, Laboratwa Famasetik, Laboratwa Kilti Selilè |
| Vitès Max | 6000rpm |
| Max.RCF | 4752xg |
| Max.Capacity | 4 * 1000ml |
| Matche Rotor | Rotor ang fiks, bokit balanse |
| Display | LCD |
| Nimewo Modèl: | DL-5M |
| sètifikasyon: | CE, ISO13485, ISO9001, SFDA |
| garanti | 1 ane garanti pou machin nan antye, 3 ane garanti pou COMPRESSOR a ak 5 ane garanti pou motè a. Pati ranplasman gratis ak anbake nan garanti. |
- Deskripsyon
- Videyo
- Espesifikasyon teknik
- Rotor ak Pwodwi pou Telefòn
- konpetitif Advantage
Floor standing refrigerated centrifuge DL-5M which can process the large capacity fixed rotor such as4*1000ml and can also process the swing out rotor ,widely used in the the fields of blood stations, pharmaceutical factories, biochemistry, biological products, etc. It is the ideal instrument for blood separation, protein precipitation and cell collection and conforms to CE security certification, ISO9001 and 13485 quality certification.
konsepsyon
● Lojman metal, kouvèti metal, ak chanm santrifij asye pur yo se detèjan otoklav-kapab ak rezistan ak likid dezenfeksyon.
● Obsèvasyon fenèt sou kouvèti pou kalibrasyon vitès ak mezi bri.
● Mikwoprosesè kontwòl ak frekans konvèsyon AC motè kondwi
● LCD Montre paramèt vitès, revèy, RCF, rotor, pwogram (memwa), akselerasyon & ralantisman enfòmasyon ak enfòmasyon kòd erè.
● Doub kouch sele bag te fè pou kouvèti santrifujeur a ak enstriman an kenbe lontan bon sele.
● Bio-sekirite: gaz-sere tèt wotasyon ki ka esterilize nan tanperati ki wo, kavite santrifujeur ak fonksyon esterilizasyon iltravyolèt, antre nan eta a esterilizasyon apre vire sou machin nan.
● Multi-kouch konsepsyon pou adaptè, travayabl pou tib 100mm ak 75mm, otomatikman retire kouvèti a, amelyore efikasite.
● Bio-sekirite: gaz-sere tèt wotasyon ki ka esterilize nan tanperati ki wo, kavite santrifujeur ak fonksyon esterilizasyon iltravyolèt, antre nan eta a esterilizasyon apre vire sou.

Fasil pou itilize
● Pwogramasyon ak estoke, estoke jiska 30 pwogram epi li bay aksè dirèk itilizatè a ak yon sèl sove kle. Paramèt ki estoke: konbinezon rete nan memwa a menm apre santrifujasyon an te etenn.
● Bay 10 pousantaj akselerasyon ak 10 ranp frenaj, pou evite efektivman sedimantasyon segondè, ak pi bon efè santrifujasyon.
● Otomatik kouvèti-bloke ak kenbe pandan rotor kouri
● Fasil echanjeur rotor, espesyal connecteur rotor ki fè li fasil pou chaje ak dechaje rotor.
● Depanaj otomatik ak endikasyon kòd erè ak alam sou ekran an.
● "Bèbè" teknoloji patant. Nivo bri pi ba pase 55 desibèl nan vitès wotasyon ki pi wo a.
● Otomatik rpm / rcf konvèsyon
● Sistèm idantifikasyon otomatik rotor, idantifikasyon rotor kode anpeche rotor la depase vitès.
● CFC sistèm refrijerasyon gratis, karakteristik pre-refwadisman, kontwòl tanperati egzak jiska - 20 ° C.

Sekirite
● Pwodui dapre règleman sekirite entènasyonal yo (eg IEC 61010)
● Sekirite Elèktrik kouvèti kouvèti, pòt pa ka louvri lè rotor ap kouri ak machin pa pral kouri lè kouvèti a louvri epi kòd erè parèt.
● Ijans kouvèti-lock lage lè echèk kouran (trè itil nan yon entèripsyon pouvwa inatandi).
● Gon gaz pou pwoteksyon gout kouvèti.
● Pwoteksyon sekirite yo te fè pou sou vitès la, sou chofaj (motè, chanm), move balans elatriye asire sekirite machin nan nonm.

| Ranje vitès (rpm) | 0-6000rpm reglabl | Ranje tan | 1-99 minit reglabl |
| Kapasite maksimòm (ml) | 4 * 1000ml | Presizyon vitès | ± 10r / min |
| Ranje RCF (xg) | 0-4752xg reglabl | ACC/DEC | 1-10 pousantaj |
| Ranje kontwòl tanperati | -20 ℃ ~ + 40 ℃ | Presizyon kontwòl tanperati | ± 1 ℃ |
| Bri (dBA) | <58dB (A) | Pwa nèt (san rotor) | 200KGS |
| Pouvwa materyèl | AC220V, 50HZ, 10A, 1800W | Dimansyon (mm) | 790x670x900mm (LxWxH) |
| No | Atik | Maks. kapasite | Vitès maksimòm | Max.RCF | nòt |
NO.1
| Ang rotor | 12x 15/10/5ml | 6000r / min | 4588xg | PP/PC tib |
| Adaptè | 12x2ml | PP/PC tib | |||
NO.2 | Balanse rotor | Rotor ankadreman asye | 5000r / min | 4752xg | PP/PC tib |
| Balanse ankadreman | 4x100ml | PP/PC tib | |||
| Balanse ankadreman | 4x50ml | PP/PC tib | |||
| Adaptè | 4x10/15ml | PP/PC tib | |||
N0.3 | Balanse rotor | Rotor ankadreman asye | 4000r / min | 3041xg | PP/PC tib |
| Balanse ankadreman | 4 × 2 × 100ml | PP/PC tib | |||
| Balanse ankadreman | 4 × 2 × 50ml | PP/PC tib | |||
| Balanse ankadreman | 4×8×15/10/5ml | PP/PC tib | |||
| Adaptè | 4×2×10/15ml | PP/PC tib | |||
| Etajè | 4×12×5/2ml | PP/PC tib | |||
NO.4 | Balanse bokit | 4 × 18×5/2ml | 4000r / min | 2773xg | Tib koleksyon san vakyòm |
NO.5 | Balanse bokit | 4 × 600ml | 4000r / min | 3354xg | Tas rektangilè pandye |
| Decapping adaptè | 4×25×5/2ml | PP/PC tib | |||
| Adaptè | 4×12×15/10ml | PP/PC tib | |||
| Adaptè | 4 × 5 × 50ml | PP/PC tib | |||
| Adaptè | 4 × 4 × 100ml | PP/PC tib | |||
NO.6 | Balanse bokit | 6 × 600ml | 4000r / min | 3400xg | Tas rektangilè pandye with wind cover |
| Decapping adaptè | 6×25×5/2ml | PP/PC tib | |||
| Adaptè | 6×12×15/10ml | PP/PC tib | |||
| Adaptè | 6 × 5 × 50ml | PP/PC tib | |||
| Adaptè | 6 × 4 × 100ml | PP/PC tib | |||
| NO.7 | Balanse bokit | 4 × 500ml | 4000r / min | 3354xg | wonn pandye tas |
| Adaptè | 4×17×5/2ml | PP/PC tib | |||
| Adaptè | 4×8×15/10ml | PP/PC tib | |||
| Adaptè | 4 × 3 × 50ml | PP/PC tib | |||
| Adaptè | 4 × 100ml | PP/PC tib | |||
| NO.8 | Balanse bokit | 6 × 500ml | 4000r / min | 3400xg | wonn pandye cup with wind cover |
| Adaptè | 6×17×5/2ml | PP/PC tib | |||
| Adaptè | 6×8×15/10ml | PP/PC tib | |||
| Adaptè | 6 × 3 × 50ml | PP/PC tib | |||
| Adaptè | 6 × 100ml | PP/PC tib | |||
| NO.9 | Balanse bokit | 4 × 800ml | 4000r / min | 3443xg | Rectangular hanging cup with wind cover |
| Decapping adaptè | 4×30×5/2ml | PP/PC tib | |||
| Adaptè | 4×12×15/10ml | PP/PC tib | |||
| Adaptè | 4 × 6 × 50ml | PP/PC tib | |||
| Adaptè | 4 × 4×100ml | PP/PC tib | |||
| NO.10 | Balanse bokit | 4 × 750ml | 4000r / min | 3443xg | Tas pandye won |
| Adaptè | 4×26×5/2ml | PP/PC tib | |||
| Adaptè | 4×13×15/10ml | PP/PC tib | |||
| Adaptè | 4 × 5 × 50ml | PP/PC tib | |||
| Adaptè | 4 × 3×100ml | PP/PC tib | |||
| NO.11 | Balanse bokit | 4 × 1000ml | 4000r / min | 3578xg | Rhomboid hanging cup with wind cover |
| Decapping adaptè | 4×42×5/2ml | PP/PC tib | |||
| Adaptè | 4×18×15/10ml | PP/PC tib | |||
| Adaptè | 4 × 7 × 50ml | PP/PC tib | |||
| Adaptè | 4 × 4×100ml | PP/PC tib | |||
| NO.12 | Microplat rotor | 4 × 2 × 96 twou | 4200r / min | 3284xg | 4×2×96 Deep hole plate 4×4×96 Shallow hole plate |
| Adaptè | 4 × 32×1.5ml | ||||
![]() | |||||
1.Professional santrifujeur manifakti, pri konpetitif.
2.ISO9001, ISO13485, CE, SFDA Sètifikasyon, tout machin sibi tès kalite strik ak bon anbalaj anvan transpò.
3.Sipò teknik alontèm ak sèvis kliyan pwofesyonèl nan chak etap nan lavant pwodwi, livrezon ak operasyon. Ekip sèvis trè kalifye ak ki gen eksperyans nou an bay ou ak yon nivo inik nan sipò pou achte ou pou tout lavi li a.
4.Nou ka ofri tou solisyon Customized pou kondisyon espesyal kliyan yo.
5.Powered ak yon ekip efikas nan enjenyè te sipòte pa ane eksperyans nan nan jaden respektif yo, konpayi an asire chak ak chak pwodwi ki kite inite fabrikasyon an se jiska mak la nan tout respè.

EN
AR
BG
HR
CS
DA
NL
FI
FR
DE
EL
IT
JA
KO
NO
PL
PT
RO
RU
ES
SV
CA
TL
IW
ID
LV
LT
SR
SK
SL
VI
SQ
HU
MT
TH
TR
FA
AF
MS
GA
BE
AZ
KA
MN
KK
UZ